Chapter 5 CANopen Operation Mode
ASDA A2-E
5-20
Revision April, 2015
1
Trigger with zero impulse signal
11
0
Reserved
12
0
Switch off sampling at positive edge of touch
probe 2
1
Enable sampling at positive edge of touch probe 2
13
0
Switch off sampling at negative edge of touch
probe 2
1
Enable sampling at negative edge of touch probe
2
14
、
15
Reserved
5.10.3 Touch Probe Status
The current status of Touch Probe can be obtained by object 60B9h. The definition of
each bit is as the followings.
Bit
Value
Definition
0
0
Touch probe 1 is switched off
1
Touch probe 1 is enabled
1
0
Touch probe 1 has no positive edge value stored
1
Touch probe 1 has positive edge value stored
2
0
Touch probe 1 has no negative edge value stored
1
Touch probe 1 has negative edge value stored
3 ~ 5
0
Reserved
6
0
Trigger with touch probe 1 input
1
Trigger with zero impulse signal
7
0,1
Toggle with every update of Touch probe 1 value
Stored
8
0
Touch probe 2 is switched off
1
Touch probe 2 is enabled
9
0
Touch probe 2 has no positive edge value stored
1
Touch probe 2 has positive edge value stored