6.11.10.2 Version V4.x
Procedure
1. Select the menu entry [Tools
→
Import Fieldbus Device...].
2. Select the XDD file for the PSM 510, DAM 510, or ACM 510 from its location on the hard drive. The device is then known to
Automation Studio™.
Power Supply Module (PSM 510):
0x0300008D_PSM.xdd
Decentral Access Module (DAM 510):
0x0300008D_DAM.xdd
Auxiliary Capacitors Module (ACM 510):
0x0300008D_ACM.xdd
3. Now add the PSM 510, DAM 510, or ACM 510 to the Ethernet POWERLINK
®
interface of the controller in the
Physical View
:
Select the menu entry[Open
→
System Designer] to show the
System Designer
.
To add a hardware module to the
Physical View
or
System Designer
, select the PSM 510, DAM 510, or ACM 510 in the group
POWERLINK
in the
Hardware Catalog
toolbox.
Drag the selected module to the desired position to connect it to the selected hardware module, network interface, or slot.
To change the node number, right-click on the device and select [Node
→
Change Node Dumber].
PSM: Danfoss _VLT_R_PSM
DAM: Danfoss _VLT_R_DAM
ACM: Danfoss _VLT_R_ACM
e3
0b
h5
16
.1
0
Illustration 67: 1 PSM 510, 1 DAM 510, and 2 ISD 510 Servo Drives Added to the Ethernet POWERLINK
®
Interface in V4.x
Commissioning
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 95
Danfoss A/S © 2019.10