3.3.5.2 Connectors on the Bottom of SDM 512
e
3
0
b
g
4
4
8
.1
0
1
2
3
4
5
6
1 Motor feedback connector SDM2
3 Motor brake and thermistor connector SDM1
5 Motor brake and thermistor connector SDM2
2 Motor feedback connector SDM1
4 Motor connector SDM1
6 Motor connector SDM2
Illustration 14: SDM 512, Enclosure Size 1 (FS1)
3.4 Decentral Access Module DAM 510
3.4.1 Overview
DAM is the abbreviation for Decentral Access Module. The DAM 510 is a central interface/gateway to the decentral servo system. It is
used to connect the Danfoss VLT
®
Integrated Servo Drives ISD 510 and VLT
®
Decentral Servo Drives DSD 510 to the servo system via a
hybrid feed-in cable.
The DAM 510 supplies the decentral servo drives with DC-link, U
AUX
, STO, and the Ethernet-based fieldbus via the hybrid feed-in cable.
The DAM 510 provides functions, such as:
•
Overcurrent protection of the hybrid cable
•
Overvoltage protection
•
Charging circuit of the DC-link
•
External encoder connection
•
DC-link capacitance buffer for the decentral servo drives
The DAM 510 can be controlled via Ethernet-based fieldbus.
LEDs on the front of the DAM 510 show the operating status and warnings.
NOTICE
-
The MSD 510 system is designed for use within a control cabinet. If the STO function is used, the cabinet must be rated at
least IP54.
-
The DAM 510 has a protection rating of IP20 according to IEC/EN 60529 (except connectors, which are IP00).
-
The DAM 510 can be damaged if exposed to fluids.
An example type code for the DAM 510 is: MSD510DAM510F1C015AD6E20PLSXXXXXXXXXXXXX.
System Description
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
32 | Danfoss A/S © 2019.10
Summary of Contents for VLT MSD 510
Page 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...
Page 2: ......