Illustration 104: Logical View of Direct Ethernet-based Fieldbus Communication
WARNING
-
The logical view only shows the connectivity from a high-level software perspective and does not reflect the actual physical
topology of the network.
6.16.4.4.2 Network Settings for Direct Communication with Ethernet POWERLINK®
Disable all network protocols except TCP/IPv4 on the network interface used for direct Ethernet POWERLINK
®
communication. This
prevents other PC software or the operating system using this network interface for other tasks, such as file and printer sharing and
network discovery. Disabling these protocols reduces the number of non-relevant packets sent over the network interface and thus
reduces the overall network load.
Commissioning
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
140 | Danfoss A/S © 2019.10