5.8.2 Connecting the Brake/Thermistor Cable
Context:
1
55
8
2
3
4
e3
0b
g8
11
.1
0
1 Motor temperature –
3 Motor brake –
2 Motor tempe
4 Motor brake +
Illustration 44: Brake/Thermistor Cable
1
3
2
4
5
e3
0b
g8
12
.1
0
1 Motor PE screw
3 Cable tie for brake/thermistor cable
5 EMC plate screw
2 Brake/thermistor connector
4 EMC plate
Illustration 45: Connecting the Brake/Thermistor Cable
NOTICE
-
Use a motor with reinforced insulation between the thermistor and the motor windings (tested with 4300 V DC and
8000 V
peak
impulse).
Electrical Installation
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
66 | Danfoss A/S © 2019.10
Summary of Contents for VLT MSD 510
Page 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...
Page 2: ......