6.11.9.1 Version V3.0.90
Procedure
1. Select the menu entry [Tools
→
Import Fieldbus Device...].
2. Select the XDD file (for example,
0x0300008D_ISD510_S.xdd
or
0x0300008D_ISD510_A.xdd
) from its location on the hard drive. This
import only needs to be done once per project. The device is then known to Automation Studio™.
3. Now add the SDM 511/SDM 512 drive module or servo drive to the Ethernet POWERLINK
®
interface of the controller in the
Physical
View
:
Right-click on the controller in the
Physical View
and select [Open POWERLINK].
Right-click on the interface and select
Insert..
.
In the
Select controller module
window, select the servo drive in the group
POWERLINK Devices
.
Click on
Next
.
In the next window, enter the node number of the servo drive.
e3
0b
h5
13
.1
0
Illustration 64: Adding a Servo Drive to the Project in V3.0.90
Commissioning
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
92 | Danfoss A/S © 2019.10
Summary of Contents for VLT MSD 510