•
Installation may only be performed by qualified personnel.
•
Installation must be performed with due care and attention.
•
All safety regulations and protective measures must be complied with, and the environmental conditions must be observed.
•
The manual is read and understood.
4.5 Installation Environment
4.5.1 System Components
The environmental conditions for the MSD 510 system components are:
•
The allowable operating ambient temperature range and vibration levels must not be exceeded (see
and Environmental Conditions for MSD 510 System
).
•
The allowable relative humidity range is 5–93%, non-condensing.
•
The minimum space required above and below the system modules is detailed in
4.7.1 Space Requirements for System Modules
.
4.6 Preparation for Installation
4.6.1 System Modules
Context:
Make the following preparations to ensure that the servo system can be installed reliably and effectively.
Always fit the system modules in accordance with local regulations.
Procedure
1. Provide a suitable mounting arrangement for the application. This depends on the type and weight of the modules.
2. To avoid misalignment, ensure that the backplates are perfectly level.
3. To ensure sufficient cooling, pay attention to the specified minimum space requirements.
4. Ground the modules.
Mechanical Installation
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 49
Danfoss A/S © 2019.10
Summary of Contents for VLT MSD 510
Page 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...
Page 2: ......