Table 142: Pin Assignment of Motor Connector
Pins
(left to
right)
De‐
scrip‐
tion
Notes
Rating/parameter
1
U
SDM 511 has 1 motor
connector.
SDM 512 has 2 motor
connectors.
Nominal voltage: 400–480 V AC±10%
Nominal power: Depends on the servo drive size.
Conductor cross-section range:
•
SDM 511 2.5–20 A
rms
: Conductor cross-section range 0.2–6 mm
2
, flexible
(AWG 24–AWG 8)
•
SDM 511 40 A
rms
: Conductor cross-section range 0.75–16 mm
2
, solid or flexible
(AWG 18–AWG 4)
•
SDM 512 2.5–10 A
rms
: Conductor cross-section range 0.2–6 mm
2
, flexible
(AWG 24–AWG 8)
2
V
3
W
11.7.8.1 Motor Cable Cross-Sections for SDM 511
Table 143: Motor Cable Cross-Sections for SDM 511
SDM 511
(2.5 A
rms
)
SDM 511
(5 A
rms
)
SDM 511
(10 A
rms
)
SDM 511
(20 A
rms
)
SDM 511
(40 A
rms
)
Minimum cable cross-section for CE
(min 70 °C, Cu)
1.5 mm
2
4 mm
2
10 mm
2
Minimum cable cross-section for UL
(min 60 °C, Cu)
14 AWG
10 AWG
6 AWG
11.7.8.2 Motor Cable Cross-Sections for SDM 512
Table 144: Motor Cable Cross-Sections for SDM 511
SDM 512 (2.5 A
rms
)
SDM 512 (5 A
rms
)
SDM 512 (10 A
rms
)
Minimum cable cross-section for CE (min 70 °C, Cu)
1.5 mm
2
Minimum cable cross-section for UL (min 60 °C, Cu)
14 AWG
11.7.9 Relay Connector
The relay connector is used for a user-defined reaction and is located as follows:
•
Servo Drive Module SDM 511: 1 relay connector
•
Servo Drive Module SDM 512: 2 relay connectors
•
Power Supply Module PSM 510: 1 relay connector
•
Auxiliary Capacitors Module ACM 510: 1 relay connector
Specifications
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 225
Danfoss A/S © 2019.10
Summary of Contents for VLT MSD 510
Page 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...
Page 2: ......