STATUS PSM
DEV
SVS ST
NET ST
LINK/ACT
X1
X2
LCP
1
e3
0b
h4
23
.1
0
PS
M
5
10
1 Internal brake resistor
Illustration 59: Connection of Internal Brake Resistor on 1 PSM 510
When using 2 PSM 510 modules, connect each PSM 510 to its own internal brake resistor as shown in
(factory setting).
Alternative permitted configurations for 2 PSM 510 modules:
•
1 PSM 510 is connected to the internal brake resistor and the other is connected to an external brake resistor.
•
Both PSM 510 modules are connected to an external brake resistor. In this case, the internal brake resistor on the PSM 510 must
remain unconnected and the connector can be placed in the internal brake resistor connector holder (see
).
Paralleling or series of brake resistors is not permitted.
Electrical Installation
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
78 | Danfoss A/S © 2019.10