Field Settings from Outdoor Unit
SiUS281811EA
172
Part 5 Field Settings and Test Operation
Procedure for changing COOL/HEAT selection setting
Press the
SET
(
BS2
) button to set
the blinking LED according to the
pattern shown on the right.
Press the
RETURN
(
BS3
) button to
determine the setting.
Check the system for each condition
through LED displays. (Refer to
information in table on the right.)
Press the
RETURN
(
BS3
) button and
return to the initial status of setting
mode 1.
h
h
h
h
h
h
l
h
h
h
l
h
h
h
l
h
h
h
h
h
h
k
ON
h
OFF
l
Blink
Procedure for checking
Setting mode 1 is the initial status
(normal). In case of other status,
press the
MODE
(
BS1
) button one
time and return to the setting mode 1.
MODE
H1P
TEST
H2P
COOL/HEAT select
IND
H3P
MASTER
H4P
SLAVE
H5P
Low
noise
H6P
Demand
H7P
h
h
k
h
h
h
h
Setting (displaying) item
MODE
H1P
TEST
H2P
COOL/HEAT select
IND
H3P
MASTER
H4P
SLAVE
H5P
LOW
NOISE
H6P
DEMAND
H7P
For selection by individual outdoor
unit (factory setting)
For selection in a batch of outdoor
unit group with master unit
For selection in a batch of outdoor
unit group with slave unit
The system returns to the initial status of setting mode 1.
Current operating conditions
h
Normal
k
Abnormal
l
In preparation or in
check operation
Setting of COOL/HEAT selection
k h h
By individual outdoor
unit
h k h
In a batch of outdoor unit
group with master unit
h h k
In a batch of outdoor unit
group with slave unit
Low noise operating conditions
h
In normal operation
k
In low noise operation
Demand operating conditions
h
In normal operation
k
In demand operation
Setting mode 1 is the initial status
(normal). In case of other status,
press the
MODE
(
BS1
) button one
time and return to the setting mode 1.
Summary of Contents for SkyAir RZR-TA Series
Page 1: ...Service Manual Cooling Only 60 Hz Heat Pump 60 Hz RZR TA RZQ TA Series SiUS281811EA...
Page 202: ...SiUS281811EA 196 Part 6 Service Diagnosis 5 15 Fan Motor Connector Check for FTQ TA 311...
Page 323: ...SiUS281811EA Wiring Diagrams Part 7 Appendix 317 RZR18 24TAVJUA RZQ18 24TAVJUA 3D124495...
Page 327: ...SiUS281811EA Wiring Diagrams Part 7 Appendix 321 FHQ18 24 30PVJU FHQ36 42MVJU 3D048116C...
Page 328: ...Wiring Diagrams SiUS281811EA 322 Part 7 Appendix FAQ18 24TAVJU 3D114844B...
Page 329: ...SiUS281811EA Wiring Diagrams Part 7 Appendix 323 FBQ18 24 30 36 42 48PVJU 3D065984J...