Installation of outdoor unit
EDUS281120_a
216
RZR-P, RZQ-P(9)
3P281953-2A
English
14
Stop valve
mounting plate
Conduit mounting
plate (accessory)
Power supply wiring
(including ground wire)
or
Transmission wiring
Power supply wiring
(including ground wire)
or
Transmission wiring
Transmission wiring
between indoor unit
Ground wiring
(yellow/green)
Power supply wiring
Clamp (accessory)
Insulation tube small
(accessory)
Insulation tube large
(accessory)
Control terminal
block (X2M)
Power terminal
block (X1M)
Lock nut
Cover
Conduit
Clamp
(accessory)
Note
Be sure to avoid
contact with the
sensor and the
filed wiring.
Cover (Handle)
(accessory)
Screw
(accessory)
How to Insulation tube.
Use the insulation tube large to cover the power supply
•
wiring.
Use the insulation tube small to cover the transmission
wiring.
Joint the insulation tube with the tape and cut off the tube
•
sticking out of the outdoor unit.
tape
Insulation tube large-1
or
Insulation tube small-1
Insulation tube large-2
or
Insulation tube small-2
Cut off the sticking out
of the outdoor unit.
CAUTION
After fi nishing the electric wiring work, confi rm that all the
•
wirings are connected securely.
〈〈
Precautions when laying power wiring
〉〉
Two electric wires of different thickness cannot be connected
•
to the power terminal block.
(Slack in the electric wires may generate abnormal heat.)
Use round pressure terminals with insulting sleeve for
•
connection to the power terminal block.
If such terminals are not available for unavoidable reasons,
connect an electric wire of the same thickness to each side
as shown in the fi gure.
Power wire
Round pressure terminal
Attach insulation sleeve
Connect same-
thickness wiring
to both sides.
It is forbidden
to connect two
to one side.
It is forbidden to
connect wiring of
different thicknesses.
Make sure to observe the following items. If they are not
observed, abnormal heat may be generated by slack in electric
wires, etc.
For wiring, use the designated power wire and connect
•
fi rmly, then secure to prevent outside pressure being exerted
on the terminal board.
Use an appropriate screwdriver for tightening the terminal
•
screws.
A screwdriver with a small head will strip the head and make
proper tightening impossible.
Over-tightening the terminal screws may break them.
•
See the table below for tightening torque for the terminal
•
screws.
Tightening torque (ft·lbf)
M5
(Power supply and ground terminal block)
1.76 ~ 2.15
M4
(Shielded ground)
0.87 ~ 1.06
M3.5
(Transmission wiring terminal block)
0.58 ~ 0.72
Summary of Contents for SkyAir RZQ-P Series
Page 1: ...Cooling Only 60Hz Heat Pump 60Hz RZR P RZQ P 9 series EDUS281120_a AMERICAS ...
Page 31: ...Dimensions and service space EDUS281120_a 30 RZR P RZQ P 9 BRC2A71 Unit in 3D047341 ...
Page 33: ...Dimensions and service space EDUS281120_a 32 RZR P RZQ P 9 BRC7E818 for FAQ 3D049736 Unit in ...
Page 34: ...EDUS281120_a Dimensions and service space RZR P RZQ P 9 33 BRC4C82 for FBQ 3D049611 Unit in ...
Page 38: ...EDUS281120_a Dimensions and service space RZR P RZQ P 9 37 3D064213A ...
Page 39: ...Dimensions and service space EDUS281120_a 38 RZR P RZQ P 9 3D064213A ...
Page 41: ...Dimensions and service space EDUS281120_a 40 RZR P RZQ P 9 3D047381B ...
Page 47: ...Wiring diagrams EDUS281120_a 46 RZR P RZQ P 9 FAQ18PVJU FAQ24PVJU 3D046039D ...
Page 61: ...Safety devices list EDUS281120_a 60 RZR P RZQ P 9 8 3 FAQ FAQ18PVJU FAQ24PVJU 4D047085B ...
Page 91: ...Capacity tables EDUS281120_a 90 RZR P RZQ P 9 RZR36PVJU RZR42PVJU 3D071685 ...
Page 92: ...EDUS281120_a Capacity tables RZR P RZQ P 9 91 RZQ36PVJU9 RZQ42PVJU9 C 3D047383B ...
Page 101: ...Sound Levels Reference EDUS281120_a 100 RZR P RZQ P 9 FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU ...
Page 102: ...EDUS281120_a Sound Levels Reference RZR P RZQ P 9 101 FBQ42PVJU ...
Page 104: ...EDUS281120_a Sound Levels Reference RZR P RZQ P 9 103 RZQ42PVJU9 RZR42PVJU 4D072769 ...