![background image](http://html1.mh-extra.com/html/daikin/skyair-rzq-p-series/skyair-rzq-p-series_engineering-data_2459074007.webp)
Model name, power supply and nomenclature
EDUS281120_a
6
RZR-P, RZQ-P(9)
2.2
Nomenclature
Indoor unit
Outdoor unit (Cooling Only)
Outdoor unit (Heat Pump)
F
C
18
VJ
PA
U
Q
Standard compatibility symbol
U: United States of America
Power supply symbol
VJ: 1 phase, 208/230 V, 60 Hz
Indicates major design category
Capacity indication in cooling
18: 18,000 Btu/h 24: 24,000 Btu/h 30: 30,000 Btu/h 36: 36,000 Btu/h 42: 42,000 Btu/h
Refrigerant and Type
Q: R410A, Heat pump or Cooling only
Shape
C: Ceiling mounted cassette (Round flow)
H: Ceiling suspended
A: Wall mounted
B: Ceiling mounted duct type
Unit category
F: Air cooled split indoor unit
R
Z
18
VJ
P
U
R
Standard compatibility symbol
U: United States of America
Power supply symbol
VJ: 1 phase, 208/230 V, 60 Hz
Indicates major design category
Capacity indication in cooling
18: 18,000 Btu/h 24: 24,000 Btu/h 30: 30,000 Btu/h 36: 36,000 Btu/h 42: 42,000 Btu/h
Refrigerant and Type
R: R410A, Cooling Only
Inverter/Non inverter
Z: Inverter
Unit category
R: Air cooled split outdoor unit
R
Z
1
8
VJ
P
Q
U
9
Management s
u
ffix
Indicates slight design change
Standard compati
b
ility sym
b
ol
U: United States of America
Po
w
er s
u
pply sym
b
ol
V
J: 1 phase, 20
8
/230
V
, 60 Hz
Indicates major design category
Capacity indication in cooling
1
8
: 1
8
,000 Bt
u
/h 24: 24,000 Bt
u
/h 30: 30,000 Bt
u
/h 36: 36,000 Bt
u
/h 42: 42,000 Bt
u
/h
Refrigerant and Type
Q: R410A, Heat P
u
mp
In
v
erter/
N
on in
v
erter
Z: In
v
erter
Unit category
R: Air cooled split o
u
tdoor
u
nit
Summary of Contents for SkyAir RZQ-P Series
Page 1: ...Cooling Only 60Hz Heat Pump 60Hz RZR P RZQ P 9 series EDUS281120_a AMERICAS ...
Page 31: ...Dimensions and service space EDUS281120_a 30 RZR P RZQ P 9 BRC2A71 Unit in 3D047341 ...
Page 33: ...Dimensions and service space EDUS281120_a 32 RZR P RZQ P 9 BRC7E818 for FAQ 3D049736 Unit in ...
Page 34: ...EDUS281120_a Dimensions and service space RZR P RZQ P 9 33 BRC4C82 for FBQ 3D049611 Unit in ...
Page 38: ...EDUS281120_a Dimensions and service space RZR P RZQ P 9 37 3D064213A ...
Page 39: ...Dimensions and service space EDUS281120_a 38 RZR P RZQ P 9 3D064213A ...
Page 41: ...Dimensions and service space EDUS281120_a 40 RZR P RZQ P 9 3D047381B ...
Page 47: ...Wiring diagrams EDUS281120_a 46 RZR P RZQ P 9 FAQ18PVJU FAQ24PVJU 3D046039D ...
Page 61: ...Safety devices list EDUS281120_a 60 RZR P RZQ P 9 8 3 FAQ FAQ18PVJU FAQ24PVJU 4D047085B ...
Page 91: ...Capacity tables EDUS281120_a 90 RZR P RZQ P 9 RZR36PVJU RZR42PVJU 3D071685 ...
Page 92: ...EDUS281120_a Capacity tables RZR P RZQ P 9 91 RZQ36PVJU9 RZQ42PVJU9 C 3D047383B ...
Page 101: ...Sound Levels Reference EDUS281120_a 100 RZR P RZQ P 9 FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU ...
Page 102: ...EDUS281120_a Sound Levels Reference RZR P RZQ P 9 101 FBQ42PVJU ...