2. When using 2 remote controllers
[ PRECAUTIONS ]
1. Make sure that the ground fault circuit interrupter is
designed to protect the air conditioner from ground faults,
overloads, and short-circuiting.
2. The remote controller wiring (P1 and P2) and transmission
wiring (F1 and F2) have no polarity.
10-3 CONTROL BY 2 REMOTE CONTROLLERS (Con-
trolling 1 indoor unit by 2 remote controllers)
• Set one of the remote controllers to main and the other to sub
in the case of remote control with two remote controllers.
Switching Main/Sub
• The setting of the BRC1E71 remote controller should be
switched referring to the manual supplied with the remote
controller.
• In case of BRC1D71 remote controller.
(1) Insert a
screwdriver into the clearance between the
grooves of the lower casing and the upper casing to remove
the upper casing. (2 grooves) (The remote controller PCB is
attached to the upper casing.)
(2) Set the main/sub switch on one of the remote controller
PCBs to sub. (Keep the switch of the other remote controller
PCB set to main.)
10-4 COMPUTERIZED CONTROL (FORCED OFF
AND ON/OFF OPERATION)
(1) Wire specifications and how to perform wiring
• Connect the external input to terminals T1 and T2 of the
terminal block for remote controller.
(2) Actuation
• The following table explains FORCED OFF and ON/OFF
OPERATIONS in response to Input A.
(3) How to select FORCED OFF and ON/OFF OPERATION
• Turn the power on and then use the remote controller to
select operation.
10-5 CENTRALIZED CONTROL
• For centralized control, it is necessary to designate the group
No. For details, refer to the manual of each optional control-
lers for centralized control.
P
1
P
2
P
1
P
2
L
1
L
2
I
N
/D OUT/D
F1 F2 F1 F2
P
1
P
2
F
1
F
2
T
1
T
2
Co
n
t
r
ol
b
ox
Fo
r
u
se
wi
th
2
rem
ot
e
co
n
t
r
oll
ers
Po
wer
S
upply
208/2
3
0V
1 ~ 60Hz
Out
d
oo
r
u
ni
t
I
nd
oo
r
u
ni
t
L
1
L
2
Lo
wer
p
ar
t of
rem
ot
e
co
n
t
r
oll
er
Upp
er
p
ar
t of
rem
ot
e
co
n
t
r
oll
er
I
nser
t th
e
s
c
rewdri
v
er
h
ere
and
gen
tly
w
o
r
k
off th
e
upp
er
p
ar
t of
rem
ot
e
co
n
t
r
oll
er.
Wire specification
CONDUCTORSTRANDEDNONSHIELDEDCOPPER06#ORVINYLJACKET
Gauge
AWG18-
Length
Max. 328 ft
External terminal
Contact that can ensure the minimum appli-
cable load of 15 V DC, 1 mA.
FORCED OFF
ON/OFF OPERATION
Input “ON” stops operation (impossible by
remote controllers.)
Input OFF
→
ON turns
ON unit.
Input OFF enables control by remote con-
troller.
Input ON
→
OFF turns
OFF unit.
O
n
ly o
ne
rem
ot
e
co
n
t
r
oll
er
needs
to
be
ch
anged
i
f f
a
cto
r
y
se
tt
ings
h
a
v
e
remained
u
n
touch
ed.
S
M
S
S
M
(F
a
cto
r
y
se
tt
ing
)
Rem
ot
e
co
n
t
r
oll
er
PC
b
o
ard
F2
T1
T2
FO
R
CED
OFF
I
n
put
A
Summary of Contents for SkyAir RZQ-P Series
Page 1: ...Cooling Only 60Hz Heat Pump 60Hz RZR P RZQ P 9 series EDUS281120_a AMERICAS ...
Page 31: ...Dimensions and service space EDUS281120_a 30 RZR P RZQ P 9 BRC2A71 Unit in 3D047341 ...
Page 33: ...Dimensions and service space EDUS281120_a 32 RZR P RZQ P 9 BRC7E818 for FAQ 3D049736 Unit in ...
Page 34: ...EDUS281120_a Dimensions and service space RZR P RZQ P 9 33 BRC4C82 for FBQ 3D049611 Unit in ...
Page 38: ...EDUS281120_a Dimensions and service space RZR P RZQ P 9 37 3D064213A ...
Page 39: ...Dimensions and service space EDUS281120_a 38 RZR P RZQ P 9 3D064213A ...
Page 41: ...Dimensions and service space EDUS281120_a 40 RZR P RZQ P 9 3D047381B ...
Page 47: ...Wiring diagrams EDUS281120_a 46 RZR P RZQ P 9 FAQ18PVJU FAQ24PVJU 3D046039D ...
Page 61: ...Safety devices list EDUS281120_a 60 RZR P RZQ P 9 8 3 FAQ FAQ18PVJU FAQ24PVJU 4D047085B ...
Page 91: ...Capacity tables EDUS281120_a 90 RZR P RZQ P 9 RZR36PVJU RZR42PVJU 3D071685 ...
Page 92: ...EDUS281120_a Capacity tables RZR P RZQ P 9 91 RZQ36PVJU9 RZQ42PVJU9 C 3D047383B ...
Page 101: ...Sound Levels Reference EDUS281120_a 100 RZR P RZQ P 9 FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU ...
Page 102: ...EDUS281120_a Sound Levels Reference RZR P RZQ P 9 101 FBQ42PVJU ...
Page 104: ...EDUS281120_a Sound Levels Reference RZR P RZQ P 9 103 RZQ42PVJU9 RZR42PVJU 4D072769 ...