2.12 WEEKLY TIMER Operation
Outline
Up to 4 timer settings can be saved for each day of the week (up to 28 settings in total).
The 3 items: ON/OFF, temperature, and time can be set.
Details
R4003381
[Monday]
1-4.
6:00
8:30
17:30
22:00
77°F (25°C)
81°F (27°C)
ON
ON
OFF
OFF
ON
OFF
ON
OFF
6:00
8:30
17:30
22:00
77°F (25°C)
81°F (27°C)
ON
OFF
ON
OFF
1-4.
8:00
10:00
19:00
21:00
81°F (27°C)
81°F (27°C)
77°F (25°C)
ON
ON
OFF
OFF
ON
OFF
OFF
ON
Setting example of the WEEKLY TIMER
The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend.
Make timer settings for programs
[Tuesday]
to
[Friday]
[Saturday]
[Sunday]
Program 1
Program 2
Program 3
Program 4
Use the copy mode to make settings for Tuesday to Friday, because these settings are the same as
those for Monday.
Program 1
Program 2
Program 3
Program 4
No timer settings
Make timer settings for programs
Program 1
Program 2
Program 3
Program 4
• Up to 4 reservations per day and 28 reservations per week can be set using the WEEKLY TIMER. The effective use of the
copy mode simplifies timer programming.
• The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode and set temperature
changes. Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn off time of each day can be set. This will turn off
the air conditioner automatically if you forget to turn it off.
Summary of Contents for RX-W Series
Page 1: ... Applied Models Inverter Pair Heat Pump Service Manual SiUS092230EA Inverter Pair RX W Series ...
Page 207: ...SiUS092230EA Check Part 6 Service Diagnosis 201 15 18 24 class R25105 1 2 3 4 Multimeter ...
Page 209: ...SiUS092230EA Check Part 6 Service Diagnosis 203 15 18 24 class R20704 W V U DC_P1 DC_N1 ...
Page 239: ...SiUS092230EA Piping Diagrams Part 8 Appendix 233 RX24WMVJU9 3D141502 ...