Functions for FDMQ/FFQ Series
SiUS092230EA
76
Part 4 Functions and Control
Note
4. Room temperature adjustment by sensing (with floor sensor)
The system uses living space temperature calculated from temperatures detected by room
temperature thermistor (suction air thermistor in the indoor unit) and floor sensor, as the target
temperature.
Operation becomes more optimized by using not only suction air temperature but floor temperature.
This function is enabled when decoration panel BYFQ60C2WAW(S) and sensor kit
BRYQ60A2W(S) is connected to the main unit.
3.10 Other Functions
3.10.1 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal receiving
sound.
3.10.2 Auto-restart Function
If a power failure (even a momentary one) occurs during the operation, the system restarts
automatically in the same conditions as before when the power supply is restored to the conditions
prior to the power failure.
It takes 3 minutes to restart the operation because 3-minute standby function is activated.
3.10.3 Emergency Operation Switch (With Wireless Remote Controller)
Outline
When the wireless remote controller does not work due to battery failure or the absence thereof,
use the emergency operation switch.
Details
Start
Press emergency operation switch.
The indoor unit runs in the previous operation mode.
The system operates with the previously set airflow direction (FFQ series only).
Stop
Press emergency operation switch again.
FDMQ Series
(R24925)
Emergency
operation
switch
Summary of Contents for RX-W Series
Page 1: ... Applied Models Inverter Pair Heat Pump Service Manual SiUS092230EA Inverter Pair RX W Series ...
Page 207: ...SiUS092230EA Check Part 6 Service Diagnosis 201 15 18 24 class R25105 1 2 3 4 Multimeter ...
Page 209: ...SiUS092230EA Check Part 6 Service Diagnosis 203 15 18 24 class R20704 W V U DC_P1 DC_N1 ...
Page 239: ...SiUS092230EA Piping Diagrams Part 8 Appendix 233 RX24WMVJU9 3D141502 ...