Forced Cooling Operation
SiUS092230EA
206
Part 7 Trial Operation and Field Settings
2. Forced Cooling Operation
Outline
The forced cooling operation is allowed when both the following conditions are met.
1. The outdoor unit is not abnormal and not in the 3-minute standby mode.
2. The outdoor unit is not operating.
Protection functions have priority over all other functions during forced cooling operation.
Details
FTXR Series
With indoor unit ON/OFF switch
Press indoor unit
ON/OFF
switch for at least 5 seconds. The operation will start.
Forced cooling operation will stop automatically after about 15 minutes.
To stop the operation, press indoor unit
ON/OFF
switch.
R7000226
With the indoor unit's remote controller
1. Press
Temp
,
buttons and
Mode
button at the same time.
2. Press
Temp
,
buttons, select "
T
", and press
Mode
button for confirmation.
3. Press
Mode
button and select the cooling operation.
4. Press
On/Off
button to turn on the system.
Forced cooling operation will stop automatically after about 30 minutes.
To stop the operation, press
On/Off
button.
R7000227
Indoor unit
ON/OFF
switch
1, 3, 4
3, 4
2
4
Summary of Contents for RX-W Series
Page 1: ... Applied Models Inverter Pair Heat Pump Service Manual SiUS092230EA Inverter Pair RX W Series ...
Page 207: ...SiUS092230EA Check Part 6 Service Diagnosis 201 15 18 24 class R25105 1 2 3 4 Multimeter ...
Page 209: ...SiUS092230EA Check Part 6 Service Diagnosis 203 15 18 24 class R20704 W V U DC_P1 DC_N1 ...
Page 239: ...SiUS092230EA Piping Diagrams Part 8 Appendix 233 RX24WMVJU9 3D141502 ...