![Daikin RX-W Series Service Manual Download Page 40](http://html1.mh-extra.com/html/daikin/rx-w-series/rx-w-series_service-manual_3662825040.webp)
Outdoor Unit
SiUS092230EA
34
Part 3 Printed Circuit Board Connector Wiring Diagram
6. Outdoor Unit
6.1 RX09/12WMVJU9
Main PCB (PCB1)
1)
S20
Connector for electronic expansion valve coil
2)
S30
Connector for compressor
3)
S40
Connector for overload protector and high pressure switch
4)
S71
Connector for DC fan motor
5)
S80
Connector for four way valve coil
6)
S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
7)
HL1, HN1, S
Wire harness for terminal block
8)
E1, E2
Wire harness for ground wire
9)
HR1, HR2
Wire harness for reactor
10)
FU1, FU2
Fuse (3.15 A, 250 V)
11)
FU3
Fuse (20 A, 250 V)
12)
J5
Jumper for warmer airflow setting
Refer to page 227 for details.
13)
J6
Jumper for facility setting
Refer to page 226 for details.
14)
J9
Jumper for drain pan heater
Refer to page 228 for details.
15)
LED A
LED for service monitor (green)
16)
V2, V3, V150
Varistor
Summary of Contents for RX-W Series
Page 1: ... Applied Models Inverter Pair Heat Pump Service Manual SiUS092230EA Inverter Pair RX W Series ...
Page 207: ...SiUS092230EA Check Part 6 Service Diagnosis 201 15 18 24 class R25105 1 2 3 4 Multimeter ...
Page 209: ...SiUS092230EA Check Part 6 Service Diagnosis 203 15 18 24 class R20704 W V U DC_P1 DC_N1 ...
Page 239: ...SiUS092230EA Piping Diagrams Part 8 Appendix 233 RX24WMVJU9 3D141502 ...