SiUS092230EA
Troubleshooting for FTXR Series
Part 6 Service Diagnosis
133
Note
5.5 Front Panel Open/Close Fault
Error Code
C7
Error Decision
Conditions
If the error repeats, the system is shut down.
Supposed
Causes
Defective reduction motor
Malfunction or deterioration of the front panel mechanism
Defective limit switch
Troubleshooting
You cannot operate the unit by the remote controller when the front panel mechanism breaks down.
<To the dealers: temporary measure before repair>
1. Turn off the power.
2. Remove the front panel.
3. Turn on the power.
(Wait until the initialization finishes.)
Operate the unit by the indoor unit
ON/OFF
switch.
YES
YES
YES
YES
NO
NO
NO
NO
Replace the harness and
reduction motor.
Replace the assembly of the
front panel mechanism.
Check the movement of the
right and left separately by
hand.
Replace the assembly of the
front panel mechanism.
It is supposed such as
deformation of the panel or
stuffed dust.
Find out the cause.
Replace the limit switch.
(R17249)
Caution
Does the front
panel move?
Does the front
panel mechanism
move?
Does the front
panel open/close fully?
Restart. Does the
error code reappear?
Restart and check the
movement.
Remove the front panel and
check the movement.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Summary of Contents for RX-W Series
Page 1: ... Applied Models Inverter Pair Heat Pump Service Manual SiUS092230EA Inverter Pair RX W Series ...
Page 207: ...SiUS092230EA Check Part 6 Service Diagnosis 201 15 18 24 class R25105 1 2 3 4 Multimeter ...
Page 209: ...SiUS092230EA Check Part 6 Service Diagnosis 203 15 18 24 class R20704 W V U DC_P1 DC_N1 ...
Page 239: ...SiUS092230EA Piping Diagrams Part 8 Appendix 233 RX24WMVJU9 3D141502 ...