Main Functions
Si12-411A
82
Function and Control
1.9
Inverter Powerful Operation
Outline
In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Details of the
Control
When Powerful button is pushed in each operation mode, the fan speed / setting temperature
will be converted to the following states in a period of twenty minutes.
In case of Wall Mounted Type 50 / 60 / 71 Class.
Ex.) : Powerful operation in cooling mode.
Operation mode
Fan speed
Target set temperature
Cooling
H tap + 90 rpm
18°C
Dry
Dry rotating speed +
50 rpm
Normally targeted
temperature in dry
operation; Approx. - 2°C
Heating
H tap + 90 rpm
30°C
Fan
H tap + 90 rpm
—
Automatic
Same as cooling /
heating in Powerful
operation
The target is kept
unchanged
(R4571)
Target temp.
Fan
90rpm
Set temp.
18˚C
Powerful ON
Powerful OFF
H tap
Set tap
It should be the lower limit of cooling temperature.
It counts 20 min. also in the remote controller.
Ending condition: "or" in 1 to 3
1. TPF ends.
2. Stop
3. Powerful operation is OFF.
TPF=(20min.)
Summary of Contents for FTKE25BVM
Page 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Page 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...Si12 411A vi Table of Contents...
Page 67: ...Specifications Si12 411A 56 Specifications...
Page 173: ...Instruction Si12 411A 162 System Configuration...
Page 227: ...Check Si12 411A 216 Service Diagnosis...
Page 295: ...Si12 411A iv Index...
Page 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...