Instruction
Si12-411A
138
System Configuration
2.8
OUTDOOR UNIT SILENT Operation
OUTDOOR UNIT SILENT Operation
OUTDOOR UNIT SILENT operation lowers the noise
level of the outdoor unit by changing the frequency and
fan speed on the outdoor unit. This function is conve-
nient during night.
■
To start OUTDOOR UNIT
SILENT operation
1. Press “SILENT button”.
■
To cancel OUTDOOR UNIT
SILENT operation
2. Press “SILENT button” again.
NOTE
■
■
■
■
Note on OUTDOOR UNIT SILENT operation
• If using a multi system, this function will work only when the OUTDOOR UNIT SILENT
operation is set on all operated indoor units.
However, if using priority-room setting, see “Note for multi system”.
• This function is available in COOL, HEAT, and AUTO modes.
(This is not available in FAN and DRY mode.)
• POWERFUL operation and OUTDOOR UNIT SILENT operation cannot be used at the
same time.
Priority is given to POWERFUL operation.
• If operation is stopped using the remote controller or the main unit ON/OFF switch when
using OUTDOOR UNIT SILENT operation, “
”will remain on the remote controller
display.
C
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
SWING
SILENT
SENSOR
ON
CANCEL
OFF
1, 2
Summary of Contents for FTKE25BVM
Page 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Page 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...Si12 411A vi Table of Contents...
Page 67: ...Specifications Si12 411A 56 Specifications...
Page 173: ...Instruction Si12 411A 162 System Configuration...
Page 227: ...Check Si12 411A 216 Service Diagnosis...
Page 295: ...Si12 411A iv Index...
Page 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...