Wiring Diagrams
Si12-411A
280
Appendix
4MXS80CVMA
ROOM D
ROOM C
ROOM B
ROOM A
TO INDOOR UNIT
3
3
3
3
2
2
2
2
1
1
1
1
FIELD WIRING
V2~V5
: VARISTOR
MRC/W
: MAGNETIC RELAY
MRB, MRD
S2~S102
: CONNECTOR
E, AC1, AC2
L2,
: CONNECTOR
HE, HL, HN
Y1E~Y4E
: ELECTRONIC EXPANSION VALVE COIL
R1T~R12T
: THERMISTOR
H1P~H5P
: PILOT LAMP
Z1C~Z3C
: FERRITE CORE
MRM10, MRM20
X1M~X5M
: TERMINAL STRIP
H1, H2, L1
FU1, FU2. FU201
: FUSE
X5M
X4M
X3M
X2M
X1M
L
3
3
3
3
2
2
2
2
N
1
1
1
1
GRN
30A
FU1
YLW
SA1
MID1
V3
Z3C
HE
1
7
HL
S11
HN
GRN
WHT
WHT
WHT
WHT
RED
BLK
YLW
AC2
AC1
H5P
1
E
1
S2W
S10
S15
BLU
V2
BLU
H4P
7
1
5
1
BLU BLU
H3P
S5W
S51
S52
BLU BLU
N
: NEUTRAL
S3W
: WIRING ERROR CHECK SW (SW3)
S4W
: PRIORITY ROOM SETTING SW (SW4)
S5W
: NIGHT QUIET MODE SETTING SW (SW5)
S2W
: FORCED OPERATION MODE SELECT SW( SW2)
L
: LIVE
H2P
PCB
: PRINTED CIRCUIT BOARD
DB1
: DIODE BRIDGE
S1W
: FORCED OPERATION ON/OFF SW (SW1)
L1R
: REACTOR
SA1
: SURGE ARRESTER
Y1S
: DEFROST SOLENOID VALVE COIL
Y1R
: REVERSING SOLENOID VALVE COIL
M1F
: FAN MOTOR
CT1
: CURRENT TRANSFORMER
M1C
: COMPRESSOR MOTOR
Q1L
: OVERLOAD PROTECTOR
BLU BLU
S1W
H1P
BLU BLU BLU
12
S2
12
BLU
S3W
1
1
RED
S102
S101
BLK
V5
S4W
WHT
5
5
GRN
MRM20
MRM10
FU2
3.15A
MRB
1
MRD
Y1S
BLU
MRC
W
Y1R
BLK
S80
CT1
BLU
9
BLK
H2
H1
S91
1
WHT
YLW
BLU
t
°
SPM
: SYSTEM POWER MODULE
MID1~MID2
: MOLDED INTER CONNECT DEVICE
YL
W
Y1E
S20
R12T
1
M
A
ORG
BLK
Z2C
BLU
3
BRN
6
RED
1
WHT
~
DB1
~
1
BLK
YL
W
+
-
Y2E
S21
BLK
M
B
ORG
BLK
BLU
BLK
RED
PCB
BLK
BRN
5
6
BLK
RED
S32
1
CN11
WHT
5
YL
W
1
Y3E
S22
+
-
M
C
ORG
ORG
L1
1
1
BLU
BLK
BRN
BLK
6
SPM
RED
BLK
TERMINALS OF THE COMP.
ASSIGNMENTS OF
BLK
CN14
1
WHT
BLK
ORG
L2
YL
W
BLK
Y4E
S23
L1R
Z1C
V
M
D
ORG
BLK
BLU
BLK
P2
W
9
N1
P1
U
W
V
U
BRN
BLK
6
10
(OUTDOOR)
RED
S31
N
R3T
1
(CONDENSER)
BLU
MID2
TB6
t
°
TB4
TB5
P2
N1
P1
R2T
S90
GR
Y
1
1
(DISCHARGE)
WHT
t
°
+
R1T
S6
ORG
BLK
6
BRN
t
°
S71
+
S72
1
BLU
+
(ROOM-A)
FU201
3.15A
R8T
1
(ROOM-B)
BLK
8
8
RED
t
°
R9T
(GAS PIPE)
GR
Y
1
1
S92
S70
BRN
t
°
(ROOM-C)
8
R10T
W
V
U
N
1
7
BRN
(ROOM-D)
t
°
RED
R11T
S33
RED
S34
8
t
°
YLW
WHT
BRN
BLU
ORG
RED
RED
BRN
BLU
(ROOM-A)
YL
W
R4T
1
BLK
(LIQUID PIPE)
(ROOM-B)
X11A
t
°
10
10
R5T
BLU
GR
Y
3D046413A
S93
t
°
YLW
BRN
BLU
RED
R6T
1
YL
W
(ROOM-C)
GR
Y
V
S40
t
°
(ROOM-D)
R7T
1
3
M1F
BLU
M1C
M
M
BLK
4
W
U
t
°
Q1L
BLK
9
N
Summary of Contents for FTKE25BVM
Page 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Page 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...Si12 411A vi Table of Contents...
Page 67: ...Specifications Si12 411A 56 Specifications...
Page 173: ...Instruction Si12 411A 162 System Configuration...
Page 227: ...Check Si12 411A 216 Service Diagnosis...
Page 295: ...Si12 411A iv Index...
Page 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...