Specifications
Si12-411A
52
Specifications
50Hz 230V
Notes:
1. The data are based on the conditions shown in the table below.
Model
3MXS52BVMB(8)
4MXS68BVMB9
Cooling
Heating
Cooling
Heating
Cooling Capacity
kW
—
—
Power Consumption
W
—
—
Running Current
A
—
—
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC32HXD
2YC45BXD
Motor Output
W
980
1,380
Refrigerant Oil
Model
FVC50K
FVC50K
Charge
L
0.65
0.75
Refrigerant
Type
R410A
R410A
Charge
kg
2.0
2.6
Air Flow Rates
m³/min
H
44
44
51
47.6
L
37
37
45
45
cfm
H
1,270
1,270
1,472
1,374
L
1,068
1,068
1,299
1,299
Fan
Type
Propeller
Propeller
Motor Output
W
53
53
Running Current
A
H: 0.24 / L: 0.17
H: 0.33 / L: 0.25
Power Consumption
W
H: 44 / L: 27
H: 68 / L: 46
Starting Current
A
6.9
8.5
Dimensions (H×W×D)
mm
735×936×300
735×936×300
Packaged Dimensions (H×W×D)
mm
784×960×357
784×960×357
Weight
kg
55
59
Gross Weight
kg
59
63
Operation Sound
dBA
46
47
48
49
Sound Power
dBA
59
60
61
62
Piping Connection
Liquid
mm
φ
6.4×3
φ
6.4×4
Gas
mm
φ
9.5×2
, φ
12.7×1
φ
9.5×2
, φ
12.7×2
Drain
mm
φ
18.0
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
No. of Wiring Connection
3 for Power Supply, 4 for Interunit Wiring
3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m
45 (for Total of Each Room)
60 (for Total of Each Room)
m
25 (for One Room)
25 (for One Room)
Amount of Additional Charge
g/m
20 (30m or more)
20 (30m or more)
Max. Installation Height Difference
m
15 (between Indoor Unit and Outdoor Unit)
15 (between Indoor Unit and Outdoor Unit)
m
7.5 (between Indoor Units)
7.5 (between Indoor Units)
Drawing No.
3D039603#1
3D039604#1
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
Summary of Contents for FTKE25BVM
Page 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Page 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...Si12 411A vi Table of Contents...
Page 67: ...Specifications Si12 411A 56 Specifications...
Page 173: ...Instruction Si12 411A 162 System Configuration...
Page 227: ...Check Si12 411A 216 Service Diagnosis...
Page 295: ...Si12 411A iv Index...
Page 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...