Main Functions
Si12-411A
74
Function and Control
1.2
Power-Airflow Dual Flaps, Wide Angle Louvers and
Auto-Swing
Power-airflow
Dual Flaps
The large flaps send a large volume of air downwards to the floor. The flap provides an optimum
control area in cooling, heating and dry mode.
Heating Mode
During heating mode, the large flap enables direct warm air straight downwards. The flap
presses the warm air above the floor to reach the entire room.
Cooling Mode
During cooling mode, the flap retracts into the indoor unit. Then, cool air can be blown far and
pervaded all over the room.
Wide-Angle
Louvers
The louvres, made of elastic synthetic resin, provide a wide range of airflow that guarantees a
comfortable air distribution.
Auto-Swing
In case of Wall Mounted Type 50 / 60 / 71 Class
The following table explains the auto-swing process for heating, cooling, dry and fan :
Outline of
3-D
Airflow
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room. This function is effective for starting the air conditioner.
Detail of the
Action
When the horizontal swing and vertical swing are both set to auto mode, the airflow become 3-D
airflow and the horizontal swing and vertical swing motions are alternated. The order of swing
motion is such that it turns counterclockwise, starting from the right upper point as viewed to the
front side of the indoor unit.
Vertical Swing (up and down)
Horizontal Swing
(right and left)
Heating
Cooling
Dry
Fan
Heating, Cooling
15˚
55˚
15˚
55˚
(R2813)
10˚
40˚ 10˚
40˚
(R2814)
5˚
35˚
5˚
35˚
(R2815)
5˚
55˚
5˚
55˚
(R2816)
50˚
50˚
(R2817)
���
���
���
���
(R1024)
Summary of Contents for FTKE25BVM
Page 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Page 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...Si12 411A vi Table of Contents...
Page 67: ...Specifications Si12 411A 56 Specifications...
Page 173: ...Instruction Si12 411A 162 System Configuration...
Page 227: ...Check Si12 411A 216 Service Diagnosis...
Page 295: ...Si12 411A iv Index...
Page 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...