Si12-411A
Specifications
Specifications
55
50Hz 230V
Notes:
1. The data are based on the conditions shown in the table below.
Model
4MXS68CVMA
4MXS80CVMA
Cooling
Heating
Cooling
Heating
Cooling Capacity
kW
—
—
Power Consumption
W
—
—
Running Current
A
—
—
Casing Color
Ivory White
Pale Ivory
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC45BXD
2YC45BXD
Motor Output
W
1,380
1,380
Refrigerant Oil
Model
FVC50K
FVC50K
Charge
L
0.75
0.75
Refrigerant
Type
R410A
R410A
Charge
kg
2.6
3.1
Air Flow Rates
m³/min
H
51
47.6
48.5
45
L
45
45
42
42
cfm
H
1,472
1,374
1,400
1,299
L
1,299
1,299
1,212
1,212
Fan
Type
Propeller
Propeller
Motor Output
W
53
51
Running Current
A
H: 0.33 / L: 0.25
H: 0.44 / L: 0.34
Power Consumption
W
H: 68 / L: 46
H: 60 / L: 41
Starting Current
A
8.5
8.7
Dimensions (H×W×D)
mm
735×936×300
908×900×320
Packaged Dimensions (H×W×D)
mm
784×960×357
1,025×926×388
Weight
kg
59
73
Gross Weight
kg
63
80
Operation Sound
dBA
48
49
48
49
Sound Power
dBA
61
62
61
62
Piping Connection
Liquid
mm
φ
6.4×4
φ
6.4×4
Gas
mm
φ
9.5×2
, φ
12.7×2
φ
9.5×2,
φ
12.7×1,
φ
15.9×1
Drain
mm
φ
18.0
φ
25.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
No. of Wiring Connection
3 for Power Supply, 4 for Interunit Wiring
3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m
60 (for Total of Each Room)
70 (for Total of Each Room)
m
25 (for One Room)
25 (for One Room)
Amount of Additional Charge
g/m
20 (30m or more)
20 (40m or more)
Max. Installation Height Difference
m
15 (between Indoor Unit and Outdoor Unit)
15 (between Indoor Unit and Outdoor Unit)
m
7.5 (between Indoor Units)
7.5 (between Indoor Units)
Drawing No.
—
3D046668
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
Summary of Contents for FTKE25BVM
Page 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Page 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...Si12 411A vi Table of Contents...
Page 67: ...Specifications Si12 411A 56 Specifications...
Page 173: ...Instruction Si12 411A 162 System Configuration...
Page 227: ...Check Si12 411A 216 Service Diagnosis...
Page 295: ...Si12 411A iv Index...
Page 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...