Si12-411A
Outdoor Unit (80 / 90 Class)
Removal Procedure
227
12
Take off the thermistor
presser spring, and
remove the thermistor.
Place the thermistor so that
its end comes up to the end
of the presser spring.
Be careful not to lose the
presser spring for the
discharge pipe thermistor.
3. Removing the electrical
box
1
Remove 2 screws of
the electrical box.
2
Turn the electrical box
up side down halfway,
and disconnect the
thermistor lead wire
from the hook.
Step
Procedure
Points