Si12-411A
Specifications
Specifications
49
Floor Standing Type
50Hz 230V
Model
FVXS25BVMB
FVXS35BVMB
Cooling
Heating
Cooling
Heating
Rated Capacity
2.5kW Class
3.5kW Class
Front Panel Color
Almond White
Almond White
Air Flow Rates
m³/min
(cfm)
H
8.1 (286)
9.2 (325)
8.3 (293)
9.2 (325)
M
6.2 (219)
7.0 (247)
6.3 (222)
7.1 (251)
L
4.3 (152)
4.8 (169)
4.3 (152)
5.0 (177)
SL
3.4 (120)
3.5 (124)
3.4 (120)
3.6 (127)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
14+14
14+14
Speed
Steps
5 Steps, Silent, Auto
5 Steps, Silent, Auto
Air Direction Control
Right, Left, Horizontal, Upward
Right, Left, Horizontal, Upward
Air Filter
Removable-Washable-Mildew Proof
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.14
0.14
0.14
0.14
Power Consumption (Rated)
W
32
32
32
32
Power Factor
%
99.4
99.4
99.4
99.4
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
600×650×195
600×650×195
Packaged Dimensions (H×W×D)
mm
714×770×294
714×770×294
Weight
kg
13
13
Gross Weight
kg
19
19
Operation
Sound
H/M/L/SL
dBA
38/32/26/23
38/32/26/23
39/33/27/24
39/34/29/26
Sound Power
H
dBA
54
—
55
—
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D040172A
3D040173A
Model
FVXS50BVMB
Cooling
Heating
Rated Capacity
5.0kW Class
Front Panel Color
Almond White
Air Flow Rates
m³/min
(cfm)
H
10.8 (381)
13.2 (466)
M
9.2 (325)
11.3 (399)
L
7.7 (272)
9.4 (332)
SL
6.7 (237)
8.3 (293)
Fan
Type
Cross Flow Fan
Motor Output
W
14+14
Speed
Steps
5 Steps, Silent, Auto
Air Direction Control
Right, Left, Horizontal, Upward
Air Filter
Removable-Washable-Mildew Proof
Running Current (Rated)
A
0.26
0.32
Power Consumption (Rated)
W
55
70
Power Factor
%
92.0
95.1
Temperature Control
Microcomputer Control
Dimensions (H×W×D)
mm
600×650×195
Packaged Dimensions (H×W×D)
mm
714×770×294
Weight
kg
13
Gross Weight
kg
19
Operation
Sound
H/M/L/SL
dBA
44/40/36/33
45/40/36/33
Sound Power
H
dBA
56
57
Heat Insulation
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
Gas
mm
φ
12.7
Drain
mm
φ
20.0
Drawing No.
3D040831
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Summary of Contents for FTKE25BVM
Page 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Page 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Page 7: ...Si12 411A vi Table of Contents...
Page 67: ...Specifications Si12 411A 56 Specifications...
Page 173: ...Instruction Si12 411A 162 System Configuration...
Page 227: ...Check Si12 411A 216 Service Diagnosis...
Page 295: ...Si12 411A iv Index...
Page 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...