xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
17
Command: show environment
Internal Power : Active
External Power : Fail
Current Temperature(Celsius) : 56
High Warning Temperature Threshold(Celsius) : 79
Low Warning Temperature Threshold(Celsius) : 11
CTRL+C
ESC
q
Quit
SPACE
n
Next Page
p
Previous Page
r
Refresh
2-10
config temperature
Description
This command is used to configure the warning trap or log state of the system internal temperature.
Format
config temperature [trap | log] state [enable | disable]
Parameters
trap
-
Specify to configure the warning temperature trap.
log
-
Specify to configure the warning temperature log.
state
-
Enable or disable either the trap or log state for a warning temperature event. The default
is enable.
enable
- Enable either the trap or log state for a warning temperature event.
disable
-
Disable either the trap or log state for a warning temperature event.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To enable the warning temperature trap state:
DGS-3620-28SC:admin#config temperature trap state enable
Command: config temperature trap state enable
Success.
DGS-3620-28SC:admin#
To enable the warning temperature log state:
DGS-3620-28SC:admin#config temperature log state enable
Command: config temperature log state enable
Success.