DES-6500 Chassis-based Layer 3 Ethernet Switch Manual
238
Figure 8- 42. Tx Error Analysis window (table)
The following fields may be set or viewed:
Parameter Description
Time Interval
[1s ]
Select the desired setting between 1s and 60s, where "s" stands for seconds. The
default value is one second.
Record Number
[200]
Select number of times the Switch will be polled between 20 and 200. The default
value is 200.
ExDefer
Counts the number of packets for which the first transmission attempt on a particular
interface was delayed because the medium was busy.
CRC Error
Counts otherwise valid packets that did not end on a byte (octet) boundary.
LateColl
Counts the number of times that a collision is detected later than 512 bit-times into the
transmission of a packet.
ExColl
Excessive Collisions. The number of packets for which transmission failed due to
excessive collisions.
SingColl
Single Collision Frames. The number of successfully transmitted packets for which
transmission is inhibited by more than one collision.
Coll
An estimate of the total number of collisions on this network segment.
Show/Hide
Check whether or not to display ExDefer, LateColl, ExColl, SingColl, and Coll errors.
Clear
Clicking this button clears all statistics counters on this window.
View Table
Clicking this button instructs the Switch to display a table rather than a line graph.
View Line Chart
Clicking this button instructs the Switch to display a line graph rather than a table.