DGS-6604
m
show poe power system
CLI Reference Guide
833
show poe power system
Use the command to display the setting and actual values of the whole POE
system.
show poe power system [
unit UNIT-ID
[ ,- ]] {power-info | parameters}
Default
None
Command Mode
EXEC mode or any configuration mode
Usage Guideline
This command could display the detail power information and PoE chip
parameters for each PoE capable unit. As list of an UNIT-ID list is specified and
not all of units in the list are PoE capable, only the PoE capable units are
displayed.
The delim sign for specifying unit list supports two choices: hyphen (-) or comma
(,). The hyphen sign is used for displaying continuous units such as unit 2 to unit
4, and the format of the list will be "2-4". If you just want to check some units
specifically like unit 3 and unit 4 which is not continuously arranged, and the
comma sign can be used.
Example
This example shows how to display PoE power system's power information.
Syntax Description
Unit
UNIT-ID
(Optional) Specifies the unit to be displayed. If no specified unit, all supported
PoE units are displayed. The value range of
UNIT-ID
is between 3 to 6.
,-
(Optional) It is possible to specify a range of
UNIT-ID
by a hyphen or a series of
UNIT-ID
by comma. There should be no spaces before or after the comma or the
hyphen.
power-info
This option could display the power information such as allocated power, used
power and unit priority of specified PoE unit.
parameters
This option could display the parameters such as max ports, device ID, software
version, EEPROM status and configuration status for PoE sub-systems.
Summary of Contents for DGS-6600 Series
Page 1: ...0 9 3 ...