DGS-6604
m
lldp hold-multiplier
CLI Reference Guide
388
lldp hold-multiplier
To set the hold multiplier for LLDP updates on the switch, use the lldp hold-
multiplier command. Use the no form of this command to return to the default
settings.
lldp hold-multiplier
VALUE
no hold-multiplier
Default
4
Command Mode
Global configuration
Usage Guideline
This parameter is a multiplier on the LLDPDUs transmission interval that used to
compute the TTL value in an LLDPDU. The lifetime is determined by hold-
multiplier times tx-interval and up to 65535. At the partner switch, when the time-
to-live for a given advertisement expires, the advertised data is deleted from the
neighbor switch's MIB.
Example
This example shows how to set LLDP hold-multiplier to 3:
This example shows how to set LLDP hold-multiplier to default value.
Syntax Description
VALUE
Specifies a multiplier on the LLDPDUs transmission interval that is used to
compute the time to the live value of an LLDPDU. Valid values are from 2 to 10.
Switch(config)# lldp hold-multiplier 3
Switch(config)# no lldp hold-multiplier