This menu is displayed if an External Heat Source has
been defined in the "Installer/Define/External Heat
Source (EHS)" menu.
System status
DHW
Shows the various operational statuses of the system.
Refer to the "Operation info/Control Unit" section.
Status On
The status of the external heat source can be "Off" or
"On".
Temperature
°
C 47
Shows the current temperature in the EHS tank.
Charge start degrees
50
This is the minimum temperature required in the external
heat source tank for the mixing valve to open and
provide heat to the system.
SmartGrid block cap.
Off
External heat source blocked by SmartGrid due to
"Overcapacity".
Mixing valve
Closes
Indicates whether the EHS tank mixing valve increases
(opens) or reduces (closes).
Demand DHW
Yes (55)
"Yes" means that there is a need for hot water and
that hot water is taken from the EHS tank. The DHW
setpoint is shown in brackets.
Demand HC
No (0)
"Yes" means that there is a need for heat in the heating
circuit and that heat is taken from the EHS tank. The
heating circuit setpoint is shown in brackets.
Demand pool
No (0)
"Yes" means that there is a need for heat in the pool and
that heat is taken from the EHS tank. The pool setpoint
is shown in brackets.
Menu: "Operation Data/External Heat Source".
12.7.7
Operation Data, External
heat source (EHS)
Summary of Contents for GSi 600 Series
Page 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Page 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Page 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Page 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Page 131: ...131 CTC GSi 600 ...
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......