51
CTC GSi 600
L1
L2
L3
1
2
3
4
Valve bedrock (Y31)
230 V 1N~
3-way valve Y31 is connected with pump G31 at the following terminal
blocks:
Expansion card (A3) X6:
Control voltage:
black
Terminal block X6:8
Phase:
brown
Terminal block X6:9
Zero:
blue
Terminal block X6:11
From electricity
distribution board
Current sensor
Fuse panel
Connect to G37–G40 on the sensor
terminal block. Use at least a 0.5 mm
2
cable.
8.12
Current sensor connection
(accessory)
The current sensors are connected at G37–G40 on the sensor terminal
block.
The three current sensors, one for each phase, are fitted on the fuse panel.
Each phase from the electricity distribution board supplying the product
is channelled through a current sensor before termination at the relevant
terminal. This allows the phase current to be sensed all the time and
compared with the value set for the heat pump’s load switch. If the current is
higher, the control unit drops to a lower heat output on the electric heater. If
this is insufficient, the heat pump is also limited. When the power drops back
below the set value, the heat pump and electric heater are reconnected. This
means that the current sensors, along with the electronics, prevent more
power being supplied than the main fuses can tolerate.
The current sensors’ cable holes are 11 mm in diameter.
The current sensor connection has no alarm, but the current value can be
read in the “Operation data” menu. Note that the tolerance/accuracy is very
low with small current values.
Summary of Contents for GSi 600 Series
Page 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Page 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Page 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Page 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Page 131: ...131 CTC GSi 600 ...
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......