85
CTC GSi 600
12.7.1
Operation data, Control unit
i
The fi rst fi gure indicates the
current operational value, and
the value in brackets indicates
the setpoint which the heat
pump is trying to achieve.
Menu Operation Data/Control Unit. Click the arrows or swipe
sideways to switch to the "Operation Data/Heat Pump" menu.
Control unit status
HC
The heat pump charges the heating circuit.
DHW
The heat pump charges the DHW system.
Pool
The heat pump charges the pool.
Click "Operation Data" in the start menu and then on the
top part of the heat pump symbol to display the "Control
Unit" menu.
Status HC
Current charging mode, see table below.
DHW tank °C
49 /45 (55)
Displays the hot water temperatures in the upper and
lower parts of the tank. The value in brackets is the
setpoint (stop
temp). The setpoint is measured in the
upper part of the tank.
Capacity 75%
Displays the estimated amount of energy remaining for
DHW.
Degree minute
-1000
Shows current heat loss in degree minutes.
Electric power kW
0.0
Shows instantaneous power from the electric heater.
Current L1/L2/L3 A
0.0 0.0 0.0
Displays current in phases L1-L3 if current sensor
installed. If not confi gured, only the highest value phase
is displayed.
i
“Degree minutes” refers to the
product of the cumulative heat loss in
degrees (°C) and the time measured
for this in minutes.
Summary of Contents for GSi 600 Series
Page 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Page 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Page 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Page 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Page 131: ...131 CTC GSi 600 ...
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......