12.10.3 Def. Heat pump
Flow/level switch
NC (None/NC/NO)
This menu bar is displayed if an "Input" for remote control
is defined for the "Flow/level switch" function in the
"Installer/Define/Define Remote Control" menu.
Noise reduct. ext. config.
None (None/NC/NO)
This menu bar is displayed if an "Input" for remote control
is defined for the "HP Noise Reduction" function in the
"Installer/Define/Remote Control" menu.
Tariff HP ext. config.
NC (None/NC/NO)
This menu bar is displayed if an "Input" for remote control
is defined for the "HP Tariff" function in the "Installer/
Define/Remote Control" menu.
12.10.4 Def. Communication
MyUplink
No (Yes/No)
Select "Yes" to connect to the heat pump from the
MyUplink app.
Web
No (Yes/No)
Select "Yes" to connect to the local web server. Internet
router and firewall required.
AXS
No (Yes/No)
Select "Yes" to connect to the SmartControl wireless
communication accessory and/or WiFi.
12.10.5 Def. DHW
Extra DHW ext. config.
None (None/NC/NO)
This menu defines the Normally Open (NO) or Normally
Closed (NC) mode for the external control signal when
remotely controlling the function.
For examples of normal mode settings, refer to the
"Def. Remote Control" section of the "Installer / Define”
chapter.
DHW circulation
No (Yes/No/DHW)
•
Yes. DHW circulation (DHW circ.) with circulation
pump G40 must be defined. This functionality option
requires the Expansion Card (A3) accessory in order
for DHW circulation to be monitored by the product.
•
DHW. Alternative with external DHW circ. pump
which is not controlled by the product. Does not
require expansion card (A3).
DHW circ. ext. config.
None (None/NC/NO)
This menu defines the Normally Open (NO) or Normally
Closed (NC) mode for the external control signal when
remotely controlling the function.
For examples of normal mode settings, refer to the
"Def. Remote Control" section of the "Installer / Define”
chapter.
Menu: "Installer/Define/Heat Pump".
Menu: "Installer/Define/Communication".
Menu: "Installer/Define/DHW".
Summary of Contents for GSi 600 Series
Page 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Page 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Page 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Page 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Page 131: ...131 CTC GSi 600 ...
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......