102
CTC GSi 600
SmartGrid Low price °C
10 (Off, 1...30)
Setting to increase temperature at energy price "Low
price", via SmartGrid.
Both SmartGrid A and SmartGrid B must be defined in the
remote control menu for this menu to be displayed.
Read more in the "Def. Remote Control /SmartGrid A/B"
section of the "Installer/Define” chapter.
SmartGrid Overcapacity °C
10 (Off, 1...30)
Setting to increase temperature at energy price
"Overcapacity", via SmartGrid.
Both SmartGrid A and SmartGrid B must be defined with
a remote control input for this menu to be displayed.
Read more in the "Def. Remote Control /SmartGrid A/B"
section of the "Installer/Define” chapter.
Run time DHW circ. (min)
4 (1 to 90)
The length of time that DHW circulation should active
during each period. Displayed if "DHW circulation" has
been defined in the "Installer/Define/DHW" menu.
Time DHW circ. (min)
15 (5...90)
Time between periods of DHW circulation. Displayed
if "DHW circulation" has been defined in the "Installer/
Define/DHW" menu.
DHW circ. schedule
This menu displays the scheduled weekday periods when
the DHW circulation pump is to run. The menu bar is
displayed if:
• "DHW circulation" has been defined in the "Installer/
Define/DHW" menu.
• a "Weekly Program" is defined for the DHW
Circulation" function in the "Installer/Define/Remote
Control" menu.
For more information, refer to:
• chapter "Weekly Program" for schedule setting.
• section "Def. Remote Control" of the
"Installer / Define" chapter for defining the remote
control function.
Time Extra DHW Remote Control (min) 0.0 (0.0...10.0)
The duration of time that extra DHW will be produced for
the DHW tank is set here. The "Extra hot water" function is
activated via remote control.
The menu bar is displayed if:
• a normal mode for the external control signal
(Normally Open (NO)/Normally Closed (NC)) is
defined for the function in the "Installer/Define/DHW
Tank" menu.
• an "Input" for "Extra DHW" has been defined in the
"Installer/Define/DHW tank" menu.
Summary of Contents for GSi 600 Series
Page 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...