113
CTC GSi 600
DHW circulation
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
The function allows DHW to circulate in the pipes
between the taps and the DHW tank, ensuring that the
DHW is hot when the taps are opened.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define/DHW" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC))
in the "DHW circulation ext. config." row.
In the "Installer/Settings/DHW" menu:
• Access function scheduling from the ”DHW circ.
schedule" row.
For more information, refer to the "DHW" section in the
"Installer/Settings" chapter.
Flow/level switch
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
The flow/level switch produces an alarm on the heat
pump.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define/Heat Pump" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC))
in the "Flow/level switch" row.
Menu: "Installer/Define/DHW".
Define a mode (Normally Open (NO) or Normally Closed (NC))
for the external control signal.
Menu: "Installer/Settings/DHW".
Setting a "DHW circulation" weekly program.
Menu: "Installer/Define/Heat Pump".
Summary of Contents for GSi 600 Series
Page 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Page 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Page 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Page 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Page 131: ...131 CTC GSi 600 ...
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......