104
CTC GSi 600
12.9.7
Settings Passive cooling
Room temperature passive cooling °C
25.0
(10.0...30.0)
This is used to set the desired room temperature for
cooling.
SmartGrid Low Price °C
1 (Off, 1...5 )
Read more in the "Installer/Define/Remote control/
SmartGrid" menu.
SmartGrid Overcapacity °C
2 (Off, 1...5)
Read more in the "Installer/Define/Remote control/
SmartGrid" menu.
Ext. block passive cooling
No (No/Yes)
Selecting "Yes" enables blocking of passive cooling. The
function can be used to turn off cooling with the help of
a humidity sensor when there is a risk of condensation.
Block passive cooling sched.
This menu is used to schedule the weekday periods
during which passive cooling should be blocked. This
schedule is repeated every week.
This menu bar is displayed if a "Schedule" has been
defined for the "Block Passive Cooling" function.
For more information, refer to:
• chapter "Weekly Program" for schedule setting.
• section "Def. Remote Control" of the
"Installer / Define" chapter for defining the remote
control function.
Menu: "Installer/Settings/Passive Cooling".