Setting the Night Reduction (-2 °C), weekday nights.
The SmartGrid function "SG Low Price" is scheduled for
weekdays Go to the menu by selecting "SmartGrid weekly
program" in the "Installer/Settings" menu.
12.6.3 Editing a weekly program
Go down to the first row and press "OK" to enable
editing mode.
Time
Use the arrow keys to change the time (hours and
minutes, respectively).
Day by day
Use the arrow keys (up arrow /down arrow) to mark
active days in bold.
Action
Off (On/Off)
This normally indicates whether the row will switch the
function "On" or "Off".
However, for the "Night Reduction" and "SmartGrid
Schedule" functions, the following applies:
• In the weekly program for "Night Reduction", the
temperature reduction that will apply during the
period is specified in °C here instead. When a
temperature is specified (setting range -1 to -30
°C), the status of the row automatically switches
to "On".
• When setting a "SmartGrid schedule", the
SmartGrid function (SG Blocking, SG Low price
and SG Overcapacity) is specified in the "Action"
row. The status of the row automatically switches
to "On".
Active
Yes (Yes/No)
"Yes" means that the row is activated.
Summary of Contents for GSi 600 Series
Page 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Page 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Page 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Page 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Page 131: ...131 CTC GSi 600 ...
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......