125
CTC GSi 600
12.11.15 Quick start compressor
When starting up the product, the compressor’s start
is delayed by 10 minutes. This function speeds up this
process.
12.11.16 Software update, USB
This is only for service engineers. This option can be
used to update the software in the display via USB. The
software update process is complete when the start
menu appears.
12.11.17 Write log to USB
This is only for service engineers. This function can be
used to save logged values to a USB memory stick.
12.11.18 Control current sensors
This is for identifying which current sensor is connected
to the relevant phase.
All three currents (L1, L2 and L3) will appear in the
current operation data when the heat pump has
identified the current transformers’ relevant phases.
In this situation it is important that you have switched
off any major consumers of electricity in the house.
Also make sure that the backup thermostat is turned
off.
12.11.19 Re-installation
This command re-launches the installation sequence
(refer to the "First start" chapter).
!
NB: The power to the product
must not be interrupted, under any
circumstances, during the update
process.
!
NB: Turn off the power and always
restart the product after software
update. Several minutes may pass
before the display communicates
clearly after restart.
Summary of Contents for GSi 600 Series
Page 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Page 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Page 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Page 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Page 131: ...131 CTC GSi 600 ...
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......