Crystal Vision
Using card edge controls
TANDEM-200 User Manual R1.7
90
13/02/2008
Setting audio delays and silence detect delay
The amount of silence detect or threshold delay can be set independently for each side in
1ms steps from 1 – 681ms using sub-menus C and D of the Status/Config menu MENU
switch all levers UP (or OFF). The silence detect delay for both sides is set using
Status/Config sub-menu E. The following table summarises the choices:
SEL
No.
Description
Examples and comments
ADJ funct
C
Audio delay side 1
Del1 xxms
Set delay ‘xx’ for side A using ADJ shaft
encoder in 1ms steps from 1 – 681ms
ADJ= delay
D
Audio delay side 2
Del2 xxms
Set delay ‘xx’ for side B using ADJ shaft
encoder in 1ms steps from 1 – 681ms
ADJ= delay
E
Silence detect delay
Sil DL xxs
Set silence detect or threshold delay for
both sides using ADJ shaft encoder for the
amount of time a signal is allowed to
remain below –50dB wrt Full Scale before a
silence error is flagged. ‘xx’ values start at
1.5s, 8s and then in increments of 8s to 120s
ADJ= silence
threshold
delay
The values for audio delay for side 1 and side 2 are entered into the TANDEM-200
database the moment the ADJ shaft encoder is turned. This has been provided to allow
delay values to be updated as soon as the shaft encoder is altered to ease the task of
setting audio delay empirically.
For all other menus, including silence detect delay, where the shaft encoder changes
assigned values, switch 1 of the MENU switch must be toggled between ON and OFF to
save the new value in the TANDEM-200 database.