Programming: Test
Merchant™ Operators’ Guide
August 2009
84
1810025
Test SureVend™ Calibration
1. Press
until you reach the
Main
Menu
, then use
or
to select
Test,
and press
.
2. In the
Test
menu, use
or
to
select
SureVend Calibration
and
press .
3. The
SureVend Calibration
screen will
display the
Calibration Values
as the
machine cycles through the SureVend
Calibration test.
NOTE
The first sensor calibration value shown
in the top line of the calibration values
is for the sensor which is located in the
back of the merchandiser, farthest from
the front door. The last sensor calibration
value shown in the bottom line of the
calibration values is for the sensor which is
located in the front, closest to the front door.
The calibration values indicate
“gain”
. The lower calibration (gain)
values are desirable. (
Optimal range
is 4
). High calibration (gain) values
indicate a problem with the sensor.
+
_
+
_
Main Menu
Data Recall
5
Diagnostic
Test
Price
Product Configuration
6
Press EDIT to Select
Test
Test Vend
5
Test Vend w/o SureVend
SureVend Calibration
Motor Test Summary
Motor Status Detail
6
Press EDIT to Select
SureVend Calibration
Calibration Values
4 5 4 5 4
4 4 4 4
Summary of Contents for Merchant Six 180
Page 1: ......
Page 7: ...Merchant Operators Guide Initial Setup 1810025 1 August 2009 FRONT EXTERIOR VIEWS ...
Page 9: ...Merchant Operators Guide Initial Setup 1810025 3 August 2009 ALL MODELS MONETARY STANDARD ...
Page 10: ...Initial Setup Merchant Operators Guide August 2009 4 1810025 INTERIOR VIEW ...
Page 204: ...Program System Settings Merchant Operators Guide August 2009 198 1810025 Service ...