Programming: Diagnostic
Merchant™ Operators’ Guide
August 2009
80
1810025
Coin Mech All Tubes Err
The coin mech is reporting errors in all the coin tubes and is out of
service.
Coin Mech Comm
Communication has been lost between the main controller and the
coin mechanism. Check wiring harnesses and coin mech.
Coin Mech Payout Jam
The coin mech is reporting that a tube payout attempt has resulted in
a jammed condition, it is still operational.
Coin Mech ROM
The coin mech is reporting a ROM failure and is out of service.
Coin Mech Tube Err
The coin mech is reporting a tube error, it is still operational.
Coin Mech Tube Sensor
The coin mech is reporting a tube sensor error, it is still operational.
Coin Return Motor Not Present
The coin return motor is not connected.
Coin Return Motor Run Time
Timeout
The coin return motor is jammed.
Coin Return Motor Short Circuit
The coin return motor is reporting a short circuit.
Coin Return Motor Drive Failure
The coin return motor is reporting a motor error.
Condenser Coil Sensor Error
An error has been reported from the condenser coil temperature
sensor or the sensor is not plugged in properly to the IO Board.
Condenser High Side Service
Required: Warning
The condenser is running at too high of a temperature for an
extended amount of time. Clean the condenser, check the fan motor
and clean the screen.
Condenser High Side Service
Required: Fatal
The condenser is running at too high of a temperature for an
extended amount of time. Clean the condenser, check the fan motor
and clean the screen. Refrigeration has been disabled; power cycle
is required to clear.
Evaporator Coil Sensor Error
An error has been reported from the evaporator coil temperature
sensor or the sensor is not plugged in properly to the IO Board.
Exec Mech Price Error
The exec coin mechanism is reporting a price error.
Factory Init Occurred
A factory initialization has occurred while the door was closed. The
door must be closed while the power is on to clear this diagnostic.
Health Control Error
On a refrigerated Merchant the cabinet temperature has exceeded
41ºF for an extended amount of time.
Init Failed
The snack motor interface has failed to initialize.
IO Board Voltage
The IO board voltage is out of the normal range.
Low Change
The machine is currently low on change. The low change threshold
is user defined.
No Errors
Indicates there are no errors in the system.
No I/O Comm
Communication between the main controller and the IO board has
been lost. Check wiring harnesses.
DIAGNOSTIC ERROR MESSAGES
Summary of Contents for Merchant Six 180
Page 1: ......
Page 7: ...Merchant Operators Guide Initial Setup 1810025 1 August 2009 FRONT EXTERIOR VIEWS ...
Page 9: ...Merchant Operators Guide Initial Setup 1810025 3 August 2009 ALL MODELS MONETARY STANDARD ...
Page 10: ...Initial Setup Merchant Operators Guide August 2009 4 1810025 INTERIOR VIEW ...
Page 204: ...Program System Settings Merchant Operators Guide August 2009 198 1810025 Service ...