(B)
(C)
(D)
(E)
Advanced
(C)
(D)
(A)
(B)
Basic
Extended
(B)
(E)
ST
ART / ST
OP
5:1
UGG050-0517
S Series
(A) = Padlock bracket, Emergency stop
(B) = Emergency stop
(C) = Start button
(D) = Stop-button
(E) = Main switch
(F) = Display
Start the granulator
5. START / STOP
1. Read page 1:3 “Safety rules, During start and opera-
tion”.
2. Read page 2:18 “Electrical cabinet, Operating panel”,
“Main switch” and “Emergency stop(s)”.
3. Check that there is no material in hopper or cutter
housing.
Important! The granulator must not be started if there
is material left in the hopper and cutter housing. When
starting, remaining material may brake the rotor and
overload the motor. The overload protection will trip
and the granulator will stop.
4. Granulator with electrical cabinet “Extended” or
“Advanced”:
Put the main switch in position “1”.
5. Granulator with electrical cabinet “Basic”:
Unlock the emergency stop’s padlock.
6. Reset the emergency stop(s).
7. Reset the IMD-system. / Reset the overload protec-
tion.
>Read page 2:25 “IMD-system”.
>Read page 2:26 “Overload protection, Motor”.
8. Start the granulator. Press the start-button.
9. The granulator is started.
Information! If the granulator or optional equipment
does not start once the above points have been
attended to, read page 7:18 “Fault tracing”.
Stop the granulator
1. Read page 2:18 “Electrical cabinet, Operating panel”,
“Main switch” and “Emergency stop”.
2. Stop feeding material. Wait until all material have
been fully granulated.
Important! Never stop the granulator until all material
in hopper and cutter housing have been fully granu-
lated.
3. Stop the granulator. Press the stop-button.
4. Press the emergency stop(s).
5. Granulator with electrical cabinet “Basic”:
Lock the emergency stop with a padlock.
6. Granulator with electrical cabinet “Extended” or
“Advanced”:
Lock the main switch in position “0”.
7. The granulator is stopped.