Advanced
I M D : C L E A N
C U T .
C H A M B E R
&
B I N
Basic
Extended
(A)
(B)
(C)
(C)
(C)
DESCRIPTION
General rules, IMD-system
The granulator can be provided with an IMD-system
“Integrated Metal Detection”. A granulator with IMD-
system is immediately stopped as any metal contamina-
tion is detected in the cutter housing. IMD-System is
optional.
The sensitivity of the IMD-system is adjustable.
The sensitivity is adjusted in different ways depending on
type of electrical cabinet.
>Page 7:5 “Adjust the IMD-system”.
Metal detection is indicated and reset in different ways
depending on type of electrical cabinet.
>Page 2:18 “Electrical cabinet, Operating panel”.
Note! Before resetting the IMD-system and before
restarting the machine, the reason why the IMD-system
tripped must be determined. Clean the machine thor-
oughly to prevent the IMD-system from immediate
tripping when restarting the machine.
Basic
Metal detection is indicated by the red warning lamp. The
IMD-system is reset by pressing the reset button.
Note! Red light can also indicate that the overload
protection has tripped.
>Page 2:26 “Overload protection, Motor”.
Extended
Metal detection is indicated by the red warning lamp. The
IMD-system is reset by putting the main switch in
position “Off”, thereafter clean the machine and finally
put the main switch back in position “On”.
Advanced
Metal detection is indicated by the red warning lamp and
a fault message on the operating panel. On the display it
is shown which scraper has detected metal, see figure to
the right. The IMD-system is reset by putting the main
switch in position “Off”, thereafter clean the machine and
finally put the main switch back in position “On”.
2. DESCRIPTION
IMD-system
(A) = Reset button
(B) = Main switch
(C) = Metal detection. Clean the granulator.