2:20
UGG050-0517
S Series
(A)
(B)
(C)
(D)
(E)
(F)
(G)
(H)
(J)
(K)
(L)
(M)
(N)
H O P P E R
O P E N
B I N
O P E N
I M D
M =
□ □ ■ □ □
F A U L T
A B S
R O T O R 1
J A M
A B S
R O T O R 2
J A M
A B S
M A S H E R
J A M
B I N
F U L L
C I R C U I T
B R E A K E R
T R I P P E D
E M E R G E N C Y
S T O P
S A F E T Y
C H A I N
< < < D A N G E R > > >
F A U L T Y
C O N T A C T O R
3
P H A S E S
I M P R O P E R
S E Q U
M A I N T E N A N C E
6 M T H
P A S S W O R D . . . : * * * *
DESCRIPTION
The following fault messages may appear on the display
of electrical cabinet “Advanced”:
(A) The hopper is opened.
Service actions: Close the hopper. Re-start the
granulator.
>Page 6:4 “Close the hopper”.
>Page 5:1 “Start the granulator”.
(B) The granule bin is opened.
Service actions: Close the granule bin. Re-start the
granulator.
>Page 6:3 “Close the granule bin”.
>Page 5:1 “Start the granulator”.
(C) The IMD-system has stopped the granulator. The
scraper that has detected metal is shown as black
on the display.
Service actions: Clean the granulator. Re-start the
granulator.
>Page 7:10 “Clean the granulator”.
>Page 5:1 “Start the granulator”.
>Page 2:25 “General rules, IMD-system”.
(D)–(F) The ABS-system has stopped the granulator.
Rotor 1, Rotor 2 or Masher-system are stuck.
Service actions: Clean the granulator. Re-start
the granulator.
>Page 7:10 “Clean the granulator”.
>Page 5:1 “Start the granulator”.
>Page 2:28 “General rules, ABS-system”.
(G) The level switch has stopped the granulator / the
optional equipment.
Service actions: Empty the granule bin. Re-start
the granulator.
>Page 7:10 “Clean the granulator”.
>Page 5:1 “Start the granulator”.
>Page 7:7 “Adjust the level switch”.
(H) The granulator ’s overload protection has tripped
since the granulator has been overloaded.
Service actions: Reset the overload protection.
>Page 2:26 “Overload protection”.
(J) The emergency stop is activated.
Service actions: Close the granulator. Reset the
emergency stop(s).
>Page 6:3 “Close the granulator”.
>Page 5:1 “Start the granulator”.
2. DESCRIPTION
Advanced, Fault messages