2:29
UGG050-0517
S Series
S918
(A)
DESCRIPTION
Timed ABS, Masher-system
“Timed ABS” = Timed reversal.
A granulator with ABS-system is provided with a timing
relay. In “Timed ABS” mode the timing relay gives signal
to reverse the Masher-system according to timed cycles
(whether the Masher-system is stuck or not). The Masher-
system’s timed ABS cycle is called “Program 1”.
Program 1, Masher-system
The operation of “Program 1” can be described as
follows:
1. Forward going operation for XX seconds.
2. Masher-system stopped for XX seconds.
3. Backward going operation for XX seconds.
4. Masher-system stopped for XX seconds.
The timing relay’s cycle times can be adjusted.
>Page 7:6 “Adjust the timing relay, Advanced”.
The Masher-system will continue repeating point 1–4
over and over again, until the Masher-system gets stuck
and stops three times in a row during a short period of
time.
If the Masher-system gets stuck and stops three times in a
row during a short period of time, the ABS-system will
automatically initiate “Program 2”.
>Page 2:33 “Program 2, Masher-system”.
2. DESCRIPTION
ABS-system
(A) = Masher-system