4:3
UGG050-0517
S Series
INST
ALLING
4. INSTALLING
Electrical connection
General rules, Electrical connection
1. Read page 4:1 “General rules, Installing”.
2. The machine must be disconnected from the mains
before electrical repairs or electrical installing is
began.
3. The machine must be installed in accordance to EN
ISO 13849-1 and EN 60204. This means, among
other, that all cables must be installed so that they will
not get damaged during operation.
4. All electrical service, must be done by authorized,
trained personnel. No modifications or alterations of
the basic electrical settings are permissible unless a
written approval has been obtained from Conair’s
head office. Refer to the electrical circuit diagram.
5. When replacing electrical components, only use
original spare parts supplied by Conair.
Emergency stop
1. Read page 4:3 “General rules, Electrical connection”.
2. Check that the supplied emergency stop is within
reach at all positions in the machine’s workplace.
3. If the supplied emergency stop is not accessible from
all positions in the workplace, the machine must be
provided with further emergency stops.
In event of any questions, please contact Conair’s
service line at 1-800-458-1960.
Connect the granulator to the mains
1. Read page 4:3 “General rules, Electrical connection”.
2. Check the phase sequence of the electric mains with a
phase sequence display. The granulator is connected
for a right-hand turning field. The electric circuit
diagram specifies the connection voltage (Volt) and
fuse size (Ampere).
3. Connect the granulator to the mains.