7:7
UGG050-0517
S Series
(C)
(D)
(A)
(D)
(E)
SER
VICE
7. SERVICE
Adjust the level switch
1. Read page 7:1 “General rules, Service”.
2. Read page 2:27 “Level switch, Granule bin”.
3. Open the granule bin. >Page 6:3.
4. Adjust the level switch’s sensitivity.
Level switch, Capacitive type:
a) Adjust the adjusting screw.
Note! Do not adjust the function screw. If the
function screw is changed, the level switch’s
function will be inversed. That is, the level switch
will alarm when the granulate level is low.
Level switch, Paddle type:
a) Unscrew the level switch’s cover.
b) Adjust the spring.
c) The level switch has 3 positions of sensibility:
High, medium and low.
d) Close the level switch’s cover.
5. Close the granule bin. >Page 6:3.
(A) = Level switch, Capacitive type
(B) = Adjusting screw
(C) = Function screw
(D) = Level switch, Paddle type
(E) = Level switch, Paddle type