7. SERVICE
Adjust the pause-pulse relay, Airveyor
1. Read page 7:1 “General rules, Service”.
2. Read page 2:8 “Additional suffix -AV”.
3. Set the working time “Ton”:
a) Select the time interval. Put the white “Ton” knob
in the desired position.
b) Select the time factor. Put the blue “Ton” knob in
the desired position.
4. Set the pause time “Toff”:
a) Select the time interval. Put the white “Toff” knob
in the desired position.
b) Select the time factor. Put the blue “Toff” knob in
the desired position.
Example:
• Working time “Ton”:
Time interval = 10 sec, Time factor = 5
• Pause time “Toff”:
Time interval = 1 min, Time factor = 2
The settings in the example means:
The airveyor will be switched on for (10 sec x 5 =) 50
seconds and will pause for (1 min x 2 =) 2 minutes.
(A) = Pause-pulse relay, Airveyor
(B) = Time interval, Working time “Ton”
(C) = Time factor, Working time “Ton”
(D) = Time interval, Pause time “Toff”
(E) = Time factor, Pause time “Toff”