7:11
UGG050-0517
S Series
M A I N T .
P E R F O R M E D
←
D A T E :
0 0 . 0 0 . 0 0
→
M A I N T E N A N C E
6 M T H
P A S S W O R D . . . : * * * *
(C)
(D)
Level 1
Level 0
Level 1
Level 0
Level 0
T I M E D
A B S
S T O P
←
0 0 0 0 0
H O U R S
→
A B S
S T O P
←
0 0 0 0 0
H O U R S
→
(A)
(B)
SER
VICE
(A) = “Maintenance request”
(B) = “Maintenance performed”
(C) = Level 0, “Timed ABS” is selected
(D) = Level 0, “Automatic ABS” is selected
Make a thorough inspection of the entire installation once
every 6 month. Check the granulator and (if supplied) the
optional equipment.
1. Read page 7:1 “General rules, Service”.
2. Execute the inspections specified in the service
schedule in the column “Once every day”.
>Page 7:1 “Service schedule”.
3. Execute the inspections specified in the service
schedule in the column “Once every week”.
>Page 7:1 “Service schedule”.
4. Execute the inspections specified in the service
schedule in the column “Once every month”.
>Page 7:1 “Service schedule”.
5. Execute the inspections specified in the service
schedule in the column “Once every 6th month”.
>Page 7:1 “Service schedule”.
6. Make a general inspection. Check that there are no
loose parts, screws, nuts or components on the
machine. Check the tightening torque on important
machine parts. Check the wear on all internal and
external machine parts. Also check machine parts
which not normally are subjected to wear.
Note! When replacing machinery parts, only use original
spare parts supplied by Conair. In event of any questions,
please contact Conair’s service line at 1-800-458-1960.
Reset “Maintenance request”
On a granulator with electrical cabinet “Advanced” a
message appears on the display every 4.400 hours of
operation. Refer to figure (A).
The message is reset as follows:
1. Execute a thorough inspection. >Page 7:11.
2. Start “Level 1”. >Page 7:6.
3. Confirm that a thorough inspection has been executed.
a) Press the edit-button “Left” until the message
“Maintenance performed” appears.
Refer to figure (B).
b) Press the edit-button “MOD” to view a cursor.
c) Enter the date of the performed maintenance.
d) Confirm by pressing the OK-button.
4. Press the edit-button “Right” until “Level 1” is
terminated and the “Level 0” message “Timed ABS”
or “ABS” appears. Refer to figure (C) or (D).
Thorough inspection
7. SERVICE